Application of IEC 61850 services for Protection, Automation, Control (PAC) functionalities and asset management applications in medium-voltage and low-voltage grid networks in Uganda. (case study Area-Kampala Metropolitan-Wandegeya Feeder)
Application of IEC 61850 services for Protection, Automation, Control (PAC) functionalities and asset management applications in medium-voltage and low-voltage grid networks in Uganda. (case study Area-Kampala Metropolitan-Wandegeya Feeder)
Date
2026
Authors
Muwanguzi, Emma.
Journal Title
Journal ISSN
Volume Title
Publisher
Makerere University
Abstract
Modernizing of the power utility networks calls for heavy reliance on robust, deterministic communication architectures to support critical Protection, Automation, and Control (PAC) functionalities alongside real-time asset management. In Uganda, particularly within the Kampala Metropolitan area, extending these capabilities to Medium-Voltage (MV) and Low-Voltage (LV) grids presents significant opportunities for enhancing overall grid reliability. Because deploying dedicated, single-use fiber infrastructure across urban distribution networks is often cost-prohibitive, exploring the integration of IEC 61850 services over shared infrastructure is highly justified. Utilizing existing Gigabit Passive Optical Network (GPON) infrastructure running through residential and municipal neighborhoods offers a highly scalable and economically viable approach to delivering critical grid telemetry, provided the strict performance thresholds of utility operations can be guaranteed. To evaluate the viability of this approach, a comparative technical methodology was executed utilizing the OMNeT++ simulation framework. The study modeled the Wandegeya Feeder's physical and logical topologies to assess data flow, interoperability, and network performance under varying traffic conditions. Two distinct network scenarios were simulated to provide a rigorous baseline: a shared GPON architecture acting as the primary test case, and a dedicated architecture featuring a completely separate fiber network acting as the control benchmark. The simulations were specifically designed to stress-test the network, measuring end-to-end latency, bandwidth consumption, and precision timing to determine if the shared medium could safely support the stringent requirements of PAC and asset management applications. The simulation results conclusively indicate the viability of running IEC 61850 services over a shared neighborhood fiber network. Bandwidth utilization on the test network never exceeded 96%, validating that ample headroom is always present to reliably support continuous asset management services without bottlenecking the network links. Furthermore, clock synchronization accuracy was not degraded by varying traffic loads; the data demonstrates that synchronization can be effectively managed and corrected in software using gPTP to ensure accuracy remains within the strict limits required for automation telemetry. Crucially, GOOSE (Generic Object-Oriented Substation Event) messaging latency stayed well within the 3-millisecond accepted safety range, peaking slightly above 960 microseconds even under extreme network stress. Because these values remained highly consistent with the performance of the dedicated benchmark architecture, the study validates that a shared GPON can successfully and securely deliver critical grid protection telemetry.
Description
A report submitted in partial fulfillment of the requirements for the award of the Degree of Bachelor of Science in Electrical Engineering of Makerere University.
Keywords
Citation
Muwanguzi, E. (2026). Application of IEC 61850 services for Protection, Automation, Control (PAC) functionalities and asset management applications in medium-voltage and low-voltage grid networks in Uganda. (case study Area-Kampala Metropolitan-Wandegeya Feeder); Unpublished dissertation, Makerere University, Kampala