dc.identifier.citationNabafu, F., & Ibanda, D. (2020). Determination of rejection rate and factors associated with rejection of conventional plain X-ray films at the Department of Radiology, Mulago National Referral Hospital. (Unpublished Undergraduate Research Report). Makerere University, Kampala, Uganda.en_US
dc.identifier.urihttp://hdl.handle.net/20.500.12281/15800
dc.descriptionA research report submitted to the Department of Radiology in partial fulfillment of the requirements for the award of the degree of Bachelor of Science in Medical Radiography of Makerere University.en_US
dc.description.abstractBackground: Reject plain X-ray film analysis can be used as a quality indicator and is an important tool in localizing areas where optimization is required. Reduction in the number of rejects is important because it reduces the effects of radiation exposure and increases efficiency in health care service delivery. Purpose: To find out the rejection rate of films and to identify factors that contributed to the rejection of films at the department of Radiology, Mulago National Referral Hospital. Material and methods: A cross-sectional study was carried out and descriptive data were collected from March to June 2020 using a structured format on which relevant data from rejected films were recorded. The results were then collected and entered into Microsoft Excel for univariate analysis from July to August 2020 and descriptive statistics generated were presented in frequency distribution tables, graphs, and pie-charts. Results: The overall reject rate was 18.9%. Chest films contributed 9.5% of the total rejection rate. 57.9% of the errors leading to film rejection were performed by radiographers with less than one year of practicing experience and the highest cause of rejection was over exposure (34.4%). Conclusions and recommendations: The findings from this study showed that the overall rejection rate was higher than the recommended 5% by WHO and up to 10% by CRPD. We therefore recommend that quality assurance and quality control programs should be put in place for optimization of service delivery.en_US
dc.language.isoenen_US
dc.publisherMakerere Universityen_US
dc.subjectResearch Subject Categories::MEDICINEen_US
dc.subjectrejection rateen_US
dc.subjectconventional plain X-ray filmsen_US
dc.subjectX-ray filmsen_US
dc.subjectDepartment of Radiologyen_US
dc.subjectMulago National Referral Hospitalen_US
dc.subjectUgandaen_US
dc.titleDetermination of rejection rate and factors associated with rejection of conventional plain X-ray films at the Department of Radiology, Mulago National Referral Hospitalen_US
dc.typeThesisen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record