Abstract
Small-scale fixed dome biogas digesters frequently underperform due to improper feeding practices rather than structural failure. This study investigated the effect of feeding practices on the performance of a cow dung fed 8 m³ fixed dome digester in Lusanja, Kawempe Division, Uganda, through a before-and-after field monitoring design comprising baseline characterization followed by implementation of a standardized feeding regime. The baseline practice was characterized by excessive organic loading rates (OLR) ranging from 2.22 to 3.27 kg VS/m³/day, a mean water-to-dung dilution ratio of 0.40, well below the recommended 1:1 minimum, and a mean substrate total solids (TS) of 12.2%, exceeding the 5–10% threshold for wet anaerobic digestion. These conditions reduced the hydraulic retention time (HRT) to a mean of 23 days, insufficient for complete digestion of cow dung. The digester exhibited no significant TVS difference (p = 0.1710) between substrate (78.7% of TS) and digestate (77.08% of TS), corresponding to a volatile solids reduction (VSR) of 8.99%. This confirmed that it was not functioning primarily as an optimized biochemical reactor. A standardized feeding regime targeting an OLR of 1.5 kg VS/m³/day at a 1:1 water-to-dung dilution ratio was designed, selecting a daily feed of 75 kg dung and 75 kg water, and was implemented. The new regime reduced the mean substrate TS to 7.8% (a 36% reduction) and the mean OLR to 1.53 kg VS/m³/day (a 44% reduction from baseline), extending the HRT to 40 days within the recommended 30–60 days range. Process stability indicators showed progressive recovery with the digestate VFA/TA ratios declining from 0.50 at implementation of the new regime (day 0) which was within the 0.4–0.6 range for emerging instability to 0.11 by day 40. The digestate pH (7.09–7.30) remained stable throughout the monitoring period and within the optimal methanogenic range. EC differed significantly under the new regime both between fresh dung and substrate (p = 0.0000) and between substrate and digestate (p = 0.0000), contrasting the non-significant baseline results (p = 0.2256 and p = 0.5502, respectively), confirming establishment of a mineralization gradient absent at baseline. Digestate VSR rose only marginally to 9.25%, consistent with literature indicating that one to two full HRT cycles are required for steady-state bioconversion. The new regime biogas production was sufficient to meet household demand with no reported supply interruptions. The findings of this study demonstrate that simple, low-cost corrections to feeding quantity and dilution ratio, without structural modification, can restore digester process parameters toward design specifications and prevent process failure, with direct relevance to the large number of underperforming household digesters across Uganda and Sub-Saharan Africa.
Description
A Project report submitted to the College of Engineering, Design, Art and Technology in partial fulfillment of the requirements for the award of the degree of Bachelor of Science in Civil Engineering of Makerere University.
Keywords
Citation
Kioko, J.N. and Ssengonzi, M. (2026). Effect of feeding practices on performance of a small-scale fixed dome digester at Lusanja-Kawempe, Uganda. ( Undergraduate Dissertation), Makerere University, Uganda.