Show simple item record

dc.contributor.authorNassali, Sandra
dc.date.accessioned2024-01-23T12:34:41Z
dc.date.available2024-01-23T12:34:41Z
dc.date.issued2023-07-11
dc.identifier.citationNassali, S. (2023). Designing and Construction of an Automatic Water Pump Level Indicator. Makerere. (Mak UD). (Unpublished Project Report). Makerere University, Kampala, Uganda.en_US
dc.identifier.urihttp://hdl.handle.net/20.500.12281/18373
dc.descriptionA project report submitted to the Department of Physics in partial fulfillment of the requirements for the award of the Degree of Bachelor of Science with Education of Makerere University.en_US
dc.description.abstractThis report presents the design and performance of an automatic water pump level indicator for multiple water tanks using ATMEGA and FPGA. The system consists of two HC-SR04 Ultrasonic transceivers that generate ultrasonic waves. The experimental results from ModelSim simulator show the system stability and efficiency both at turbulence and at high-pressure conditions. Moreover, the performance of Field programmable gate array (FPGA) to control the water pump is also studied. The design and construction of this system serve as a practical and user-friendly solution for monitoring and displaying the water level.en_US
dc.language.isoenen_US
dc.publisherMakerere University.en_US
dc.subjectAutomatic water pump.en_US
dc.subjectDesign and construction.en_US
dc.subjectUltrasonic waves.en_US
dc.subjectField programmable gate array .en_US
dc.titleDesigning and construction of an Automatic Water Pump level indicator.en_US
dc.typeTechnical Reporten_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record