A research project report to assess the efficiency of a grate cooler at Tororo cement manufacturing plant.
dc.contributor.author | Nowomujuni, Sheilah | |
dc.date.accessioned | 2021-03-09T07:55:59Z | |
dc.date.available | 2021-03-09T07:55:59Z | |
dc.date.issued | 2021-02-26 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12281/9329 | |
dc.description | A project report submitted to the Department of Chemistry, College of Natural Sciences in partial fulfilment of the award of Degree of Bachelors of Science in Industrial Chemistry of Makerere University | en_US |
dc.description.abstract | The report explains the optimization of the cooler at Tororo cement plant by varying the bed height of the cooler and the velocities of the primary fans. main objectives include bench marking the practical energy balance against the practical energy balance. Determining velocities of the fans help in finding the volumetric flow rate of the clinker. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Makerere University | en_US |
dc.subject | Grate cooler efficiency | en_US |
dc.subject | Tororo cement plant | en_US |
dc.title | A research project report to assess the efficiency of a grate cooler at Tororo cement manufacturing plant. | en_US |
dc.type | Technical Report | en_US |